Vaillant F.75 Fault: No Pressure Change When Pump Starts — Causes & What To Do
The F.75 fault means your Vaillant boiler started the pump but couldn't detect a pressure change — so it can't confirm water is circulating. It's usually a faulty pressure sensor, a seized or sticking pump, or air in the system. You can check the pressure gauge first.
What does the Vaillant F.75 fault code mean?
F.75 indicates the boiler's pressure sensor didn't register a change when the pump started, so it can't confirm water is circulating. It locks out to protect the heat exchanger from overheating. You'll usually have no heating or hot water.
Why has my boiler developed the F.75 fault?
The most common causes, in order of how often we see them:
- • Faulty pressure sensor — the sensor that detects the pressure change when the pump runs can fail, so the boiler thinks nothing is circulating even when it is. The most common F.75 cause.
- • Seized or sticking pump — if the pump isn't turning properly, no pressure change is generated and the sensor reads nothing.
- • Air in the system — trapped air can prevent a clean pressure change at the sensor, triggering F.75 intermittently.
- • Low system pressure — very low pressure can mean the pump has nothing to push, so no change is detected.
- • Blocked pump or filter — debris in the pump or system can stop circulation.
Can I reset the F.75 fault?
Repressurising to 1.2 bar and resetting can clear F.75 if low pressure or air was the cause. If pressure is normal and the fault persists, the issue is the pressure sensor or the pump — a reset won't help. Don't reset repeatedly; if it returns, book an engineer.
Can I fix this myself?
Safe homeowner checks
- Check the pressure gauge on the boiler front (healthy is 1.0–1.5 bar)
- Repressurise to 1.2 bar via the filling loop if it's low
- Bleed radiators to release trapped air, then re-check pressure
- Read the fault code and note it down
- Try one boiler reset after repressurising
Engineer required
- Replacing the water pressure sensor
- Inspecting, freeing, or replacing the pump
- Diagnosing the PCB pump and sensor signals
- Any internal work inside the boiler casing
- Re-commissioning the boiler after any internal repair
Gas work legally requires a Gas Safe Registered engineer. Tampering with gas appliances is dangerous and unlawful.
Safe checks you can make first
- • Check the pressure gauge — if it's below 0.6 bar, low pressure may be your F.75 trigger. Repressurise to 1.2 bar via the filling loop, then reset.
- • Bleed radiators to release trapped air — air can prevent a clean pressure change at the sensor. Re-check pressure afterwards, as bleeding lowers it.
- • Listen for the pump — when the boiler tries to fire, you should hear the pump run. If it's silent or humming loudly, the pump may be seized and needs an engineer.
- • If pressure is normal, radiators are bled, and F.75 persists, the fault is the pressure sensor or pump — book a Gas Safe engineer.
Need this fault diagnosed? Book a Gas Safe engineer.
What should you NOT attempt yourself?
The pressure sensor and pump sit inside the boiler casing. Replacing the sensor, freeing the pump, or any work inside the casing is gas/electrical work that must be done by a Gas Safe Registered engineer.
What will a Gas Safe engineer check?
- • Confirm system pressure on the gauge and with a calibrated reading.
- • Test the pressure sensor's response when the pump starts.
- • Inspect the pump — check it's running freely and not seized or blocked.
- • Bleed the system and check for air locks affecting the sensor reading.
- • Test the PCB pump and sensor signals to isolate the fault.
- • Replace the pressure sensor or pump as needed, then re-commission.
How Urban Suburban can help
Our Gas Safe Registered (594547) engineers repair every Vaillant model — ecoTEC, ecoFIT, atmoTEC — across Surrey, Berkshire, Buckinghamshire and West London, and carry common sensors and ignition parts on the van. Most Vaillant fault-code repairs are completed in a single visit, with any part quoted and agreed before fitting.
Related Vaillant fault codes
Frequently asked questions
What does the Vaillant F.75 fault code mean?
F.75 means the boiler started the pump but the pressure sensor didn't detect a pressure change, so it can't confirm water is circulating. It locks out to protect the heat exchanger. The usual causes are a faulty pressure sensor, a seized pump, or air in the system.
What's the difference between F.73 and F.75?
Both involve the pressure sensor, but F.73 is a pressure sensor signal fault (the boiler can't confirm there's enough water), while F.75 is a lack of detected pressure change when the pump starts (the boiler can't confirm circulation). F.75 more often involves the pump.
Can I fix the F.75 fault myself?
You can safely check the pressure gauge, repressurise, and bleed radiators. If pressure is normal and F.75 persists, the pressure sensor or pump needs replacing — that's a job for a Gas Safe Registered engineer.
How much does it cost to fix a Vaillant F.75 fault?
Labour typically runs £90–£220 plus the £150 call-out (which includes the first hour). If the pressure sensor needs replacing it's usually quick; if the pump needs replacing, the part costs more and is quoted and agreed before fitting.
Technical content & review
Technical content by URBAN SUBURBAN GAS
Gas Safe Registration: 594547 · NVQ Qualified engineers
BOOK YOUR VAILLANT BOILER REPAIR
Our Gas Safe Registered (594547) engineers repair every Vaillant model — ecoTEC, ecoFIT, atmoTEC — across Surrey, Berkshire, Buckinghamshire and West London. Book online in 60 seconds.
See our full transparent pricing page