Vaillant F.73 Fault Code: Causes & What To Do

The F.73 fault on a Vaillant boiler points to the water pressure sensor or the system pressure itself — the boiler can't confirm there's enough water to fire safely. You can safely check the pressure gauge and top up if it's low; if pressure is normal and the fault persists, the sensor or its wiring needs a Gas Safe engineer.

What does the Vaillant F.73 fault code mean?

F.73 indicates a problem with the water pressure sensor or the system pressure itself. The boiler can't confirm there's enough water in the system to fire safely, so it locks out to protect itself. It's one of the more common Vaillant ecoTEC and atmoTEC fault codes we attend.

Why has my boiler developed the F.73 fault?

The most common causes, in order of how often we see them on call-outs:

  • • Low system pressure — if pressure has dropped below roughly 0.6 bar, the sensor can't confirm water is present and the boiler locks out with F.73.
  • • Faulty pressure sensor — the sensor can fail or drift out of calibration, reporting a reading the boiler doesn't trust even when pressure is normal.
  • • Air in the system — trapped air in radiators or pipework causes erratic pressure readings at the sensor, triggering the fault intermittently.
  • • Wiring or connector fault — a loose, corroded or damaged connection between the pressure sensor and the PCB interrupts the signal and throws F.73.

Can I reset the F.73 fault?

Repressurising the system to around 1.2 bar and resetting the boiler can clear F.73 if low pressure was the cause. If the pressure gauge already reads 1.0–1.5 bar and the fault persists, a reset won't help — the sensor or its wiring needs replacing. Don't reset repeatedly; if the fault returns, book an engineer.

Can I fix this myself?

Safe homeowner checks

  • Check the pressure gauge on the boiler front (healthy is 1.0–1.5 bar)
  • Repressurise to 1.2 bar via the filling loop if it's low
  • Bleed radiators to release trapped air, then re-check pressure
  • Read the fault code on the display and note it down
  • Try one boiler reset after repressurising

Engineer required

  • Replacing the water pressure sensor
  • Testing or repairing the sensor wiring and PCB connector
  • Diagnosing the PCB signal to the sensor
  • Any internal electrical diagnosis inside the boiler casing
  • Re-commissioning the boiler after any internal repair

Gas work legally requires a Gas Safe Registered engineer. Tampering with gas appliances is dangerous and unlawful.

Safe checks you can make first

  • • Check the pressure gauge — a healthy system sits between 1.0 and 1.5 bar when cold. If it's below 0.6 bar, low pressure is almost certainly your F.73 trigger.
  • • Repressurise via the filling loop to around 1.2 bar, then reset the boiler. If the fault clears and pressure holds, the fix may be complete — but watch for it dropping again.
  • • Bleed radiators if you hear gurgling or they're cold at the top — trapped air causes erratic readings. Re-check pressure afterwards, as bleeding lowers it.
  • • If pressure reads 1.0–1.5 bar and the F.73 persists, the fault is with the sensor or its wiring — not something to attempt yourself. Book a Gas Safe engineer.

Need this fault diagnosed? Book a Gas Safe engineer.

Book boiler repair

What should you NOT attempt yourself?

The pressure sensor and its wiring sit inside the boiler casing. Replacing the sensor, testing the PCB signal, or any work inside the casing is gas/electrical work that must be done by a Gas Safe Registered engineer. If pressure is normal and F.73 persists, stop and book a repair.

What will a Gas Safe engineer check?

  • • Confirm system pressure on the gauge and with a calibrated reading.
  • • Compare the sensor's reported pressure against actual system pressure.
  • • Inspect the wiring and connector between the sensor and the PCB.
  • • Test the PCB input signal to confirm whether the fault is the sensor or the board.
  • • Replace the pressure sensor if faulty, using a manufacturer-approved part.
  • • Re-commission the boiler and verify safe combustion after the repair.

How Urban Suburban can help

Our Gas Safe Registered (594547) engineers repair every Vaillant model — ecoTEC, ecoFIT, atmoTEC — across Surrey, Berkshire, Buckinghamshire and West London, and carry common sensors and ignition parts on the van. Most Vaillant fault-code repairs are completed in a single visit, with any part quoted and agreed before fitting.

Related Vaillant fault codes

Frequently asked questions

What does the Vaillant F.73 fault code mean?

F.73 indicates a problem with the water pressure sensor or the system pressure itself. The boiler can't confirm there's enough water in the system to fire safely, so it locks out to protect itself.

Can I fix the F.73 fault myself?

You can safely check the pressure gauge and repressurise the system via the filling loop if it's low. If pressure is normal and the fault persists, the sensor or its wiring needs replacing — that's a job for a Gas Safe Registered engineer.

How much does it cost to fix a Vaillant F.73 fault?

Labour for an F.73 repair typically runs £90–£220, plus the call-out (£150, which includes the first hour). If the pressure sensor needs replacing, the part cost is quoted and agreed before fitting.

Will the F.73 fault clear on its own?

Sometimes repressurising the system and resetting the boiler clears it temporarily. But if the underlying cause is a faulty sensor, a leak, or air in the system, the fault will return until it's properly diagnosed and fixed.

Technical content & review

Technical content by URBAN SUBURBAN GAS

Gas Safe Registration: 594547 · NVQ Qualified engineers

Originally published2026-08-16
Last technically reviewed2026-08-16
Manufacturer information checked2026-08-16
Gas safety review2026-08-16

BOOK YOUR VAILLANT BOILER REPAIR

Our Gas Safe Registered (594547) engineers repair every Vaillant model — ecoTEC, ecoFIT, atmoTEC — across Surrey, Berkshire, Buckinghamshire and West London. Book online in 60 seconds.

See our full transparent pricing page
Advice Centre
5.0 · 70 reviews 24/7 response

Analytics Cookies

We use Google Analytics to understand which boiler help topics visitors search for and read most, so we can improve our advice. No Google Analytics scripts load and no Google Analytics events fire until you accept. We do not use advertising cookies. You can change this choice at any time via “Cookie Settings” in the footer.